The belt is part of the aperture
Buyers often pick a conveyor belt by wear resistance and service life alone, but the belt is part of the detection aperture itself. A metal detector works with an alternating magnetic field, so metal particles, conductive fibers or metallic threads embedded in the fabric can generate signals as they pass the coils. The result is a raised noise floor that eats into usable sensitivity, or periodic false rejects. Check whether a belt is suitable for magnetic passage before installation, not after repeated tuning.
Thickness and splice effects
Thickness and splice design matter just as much. A thicker belt increases the distance between product and sensing head, weakening the signal and reducing the ability to find small metal. If the splice uses metal hooks, steel fasteners or a thickened overlap, it gives the machine a fixed interference point on every revolution, showing up as regular alarms. Choose thin, flat belts without metal reinforcement and with a stable splice, then re-verify sensitivity after the change.
Verifying after a belt change
Procurement and quality teams can add belts to the acceptance checklist. After fitting a new belt, pass known test pieces over the left, center and right of the belt surface and confirm each position detects reliably. Run empty for several laps and watch for alarms that match the belt length cycle. When switching to a different batch or material, confirm detection capability again rather than reusing old settings. Treat the belt as a wear part, log replacement dates and verification results, and the inspection step stays trustworthy over time.
Does belt thickness affect detection?
Yes. A thicker belt increases the gap between product and sensing head, weakening signals and reducing the ability to detect small metal; metal splices add periodic interference.